TDS cannot be used to establish an antiscalant dose (Total Dissolved Solids).
The reason is that TDS may either be fully composed of calcium and sulfate, which has a very high scaling potential, or composed of sodium and chloride, which do not have a scaling potential.
The ion types in the water must be recognized, and their concentrations must be estimated using the concentration factor to establish the appropriate antiscalant and dose. The kind of membrane and the percentage of salt rejection affect the concentration factor. RO Permeate Flush is available online. The antiscalant will be chosen based on the kind of scale that is most likely to occur after we have calculated the potential for the ions in the water to create a scale.